Home » Data Center » ZutaCore Launches Z₂O Waterless Cooling System for AI Data Centers

ZutaCore Launches Z₂O Waterless Cooling System for AI Data Centers

ZutaCore Z₂O Zero water. near-zero cooling energy. Two-phase

ZutaCore has introduced Z₂O, a waterless cooling architecture designed to reduce the energy and infrastructure required to manage heat in artificial intelligence (AI) data centers. Unveiled at Supercomputing 2026 (SC26) in Chicago on Nov. 16, the system uses a unified two-phase liquid cooling loop to transfer heat directly from server processors to rooftop heat-rejection equipment, eliminating the need for conventional cooling distribution units (CDUs), facility water loops and water-based cooling towers.

Developed with cooling technology company Munters (STO: MTRS), Z₂O uses direct-to-chip cold plates and dry coolers that reject heat into outdoor air. The architecture is designed to operate without a liquid-to-liquid heat exchanger or a conventional chiller plant, reducing the number of mechanical systems required to support high-density computing infrastructure.

According to ZutaCore, the launch reference design developed with Munters achieves a modelled annualized partial power usage effectiveness (pPUE) of 1.03, with zero water consumption. The company said the configuration is designed to help data center operators direct a greater share of their available power towards IT workloads rather than cooling infrastructure.

The first installation uses an ASRock Rack server powered by NVIDIA’s (NASDAQ: NVDA) HGX B300 platform. The ASRock Rack 4U16X-GNR2/ZC is described as the first HGX B300 server with fully integrated waterless liquid cooling.

Two-phase cooling replaces conventional thermal infrastructure

Z₂O is based on ZutaCore’s two-phase direct-to-chip cooling technology, which uses a dielectric fluid to absorb heat from processors. Unlike conventional single-phase liquid cooling, where coolant remains in liquid form throughout the cooling circuit, the two-phase approach allows the fluid to boil at the chip and subsequently condense at the heat-rejection system.

The company said the fluid circulates through a unified loop, transferring heat from server cold plates to rooftop equipment, where dry coolers release it into the outdoor air. The process operates at essentially the same temperature between the chip and the condenser, allowing the system to perform the functions of several conventional thermal-management components.

The fluid is described as sealed, non-toxic, non-flammable and electrically non-conductive. Circulation relies largely on buoyancy and gravity, with pumps providing assistance and redundancy.

By integrating heat transfer and heat rejection into one loop, Z₂O removes several infrastructure requirements associated with conventional data center cooling, including CDUs, liquid-to-liquid heat exchangers, facility water circuits, cooling towers and chillers.

ZutaCore is positioning the architecture for data centers facing growing power constraints as AI workloads increase demand for high-performance computing. The company argues that reducing cooling-related electricity consumption can allow operators to allocate more of their secured power capacity to computing workloads.

Modular design targets faster data center deployment

The Z₂O architecture is built around a repeatable 625-kilowatt IT block, comprising 500 kW of two-phase liquid-cooled capacity and 125 kW of air-cooled capacity.

The configuration is intended for deployment across conventional data halls, prefabricated modular data centers and both greenfield and brownfield facilities. Its design eliminates the need to install and commission several conventional cooling systems, which ZutaCore said could simplify project planning and deployment.

The company also highlighted operational resilience as a design consideration. The system incorporates N+1 spare heat-rejection capacity and redundant pumps powered through an uninterruptible power supply (UPS). These features are intended to maintain cooling operations if individual components become unavailable.

Operators can monitor the cooling infrastructure through ZutaCore HyperCool Cloud, the company’s system visibility platform.

The architecture also addresses water availability, an increasingly important consideration for data center development. ZutaCore said Z₂O uses no facility water for either its liquid-cooled or air-cooled loads, resulting in a water usage effectiveness (WUE) of zero. This could make the system relevant to locations where water availability or restrictions on industrial water consumption create challenges for data center expansion.

Compatible with existing and next-generation cold plates

Z₂O is compatible with ZutaCore’s Two-Phase Matrix Flow Boiling OmniTherm cold plates, introduced at the OCP Global Summit in October 2026, as well as the company’s existing HyperCool cold plates.

Both technologies use the same dielectric fluid and unified cooling loop. According to ZutaCore, this allows customers to upgrade their server-level cooling technology without redesigning or re-plumbing the wider data center infrastructure.

The compatibility is intended to support future processor generations as chip power requirements increase. With semiconductor roadmaps pointing towards processors with power consumption reaching multiple kilowatts, thermal management is becoming an increasingly important consideration for AI server and data center design.

“AI operators have fought hard for every megawatt, and they should not be spending it on moving heat,” said Dan Wood, chief product officer at ZutaCore. He added that Z₂O consolidates the thermal infrastructure between the chip and outdoor air into a single two-phase loop.

Keith Dunnavant, vice president of offer strategy and portfolio management at Munters, said the combination of Munters SyCool technology and ZutaCore’s two-phase cooling architecture reduces water requirements and the mechanical infrastructure traditionally used by AI data centers.

ZutaCore demonstrates integrated cooling solutions at SC26

At SC26, ZutaCore is showcasing Z₂O and its broader two-phase cooling portfolio at booth 3850. Demonstrations include the ASRock Rack 4U16X-GNR2/ZC server with NVIDIA HGX B300, featuring factory-integrated HyperCool technology.

The company is also displaying its OmniTherm cold plate on an NVIDIA RTX PRO 6000 Blackwell Server Edition system, alongside a live RTX PRO 6000 server demonstration with real-time performance data.

Additional exhibits include a magnified view of its direct-to-die cooling technology and an interactive digital twin developed by Smart Spatial. The digital twin presents rack-level solutions from ASRock Rack, Compal (TWSE: 2324) and MiTAC (TWSE: 3706), supporting AI server configurations based on NVIDIA and AMD (NASDAQ: AMD) platforms.

ZutaCore said it will define the Z₂O architecture, working fluid and interfaces while delivering deployments through specialist technology partners. The company expects additional partner implementations in 2027.